Adjusting COEngine must be at normal operating temperature Idle speed at 880 ± 50 rpm Pull off purge line at charcoal canister and remove the tamper proof plug from the airflow meter. Connect the probe from a gas analyzer to the exhaust. Check CO and note the measured value, with oxygen sensor connected. The CO value must
be within the range of 0.2% - 1.2% Disconnect the oxygen sensor and check CO value again. Compare this value with the CO value measured with the oxygen sensor connected. If any deviation is observed, adjust the CO volume by turning the air by-pass screw on the airflow meter to the correct value. Make adjustments slowly and allow time for the system to settle before continuing adjustment. When the reading is between 0.2% - 1.2% with the oxygen sensor disconnected, reconnect sensor and purge line. Replace tamper proof plug. |
|
|